Sign up now and share your case with us
Powered by Graphy · Made in Egypt

The World's First Shape Memory Aligner

3D-printed tooth-by-tooth, powered by Graphy technology. Precise. Hygienic. Faster treatment. Made in Egypt.

Powered by Graphy ta28 Shape Memory BPA-Free & Biocompatible ISO Certified
DPA Directly Printed Aligners logo, powered by Graphy
Powered byGraphy

3D-printed clear aligners, engineered tooth-by-tooth.

About DPA

About Directly Printed Aligners

DPA is one of the leading companies in the clear aligner field, with vast experience in dentistry. We rely on the latest digital manufacturing technologies, supported by expert orthodontists who follow up on every case. This technology is powered by Graphy.

50%
Faster treatment vs. conventional
22 hrs
Recommended daily wear
1 Week
Per aligner step

Key Features

Why DPA aligners are different

Every feature is engineered — not marketed.

Zero Attachments

No Attachments Needed

DPA aligners achieve tooth movement without bonded attachments in most cases. No drilling, no bonding, no residue — fully non-invasive.

1 Week Per Step

Change Every 7 Days

Shape memory material keeps consistent force all week, enabling faster stage progression than 2-week thermoformed protocols.

Faster Movement

Up to 50% Faster Treatment

Continuous shape-memory force keeps teeth moving throughout wear. Clinical data shows up to 50% shorter treatment time.

Easy Adaptation

Warm Water Activation

Soak 30 seconds in lukewarm water — it softens, fits perfectly into undercuts, then hardens at body temperature. No forced seating.

Light & Continuous Force

Gentle, Biologically Safe

Unlike thermoformed trays with heavy initial spikes, DPA applies light continuous force — within biological limits, pain-free movement.

Custom Thickness

Customized Per Tooth

Each aligner is printed with variable thickness — thicker where force is needed, thinner where flex is required. Impossible with sheets.

Precise Fit

Exact Occlusal Reproduction

Direct 3D printing bypasses model fabrication, eliminating cumulative errors. Submillimeter-accurate fit on every tooth surface.

Superior Hygiene

Heat-Disinfectable at 100°C

Graphy aligners survive boiling water sterilization — PET/PETG cannot. Non-porous surface resists bacteria and staining.

Crystal Clear

Optically Transparent

Printed from optically clear ta28 resin — no whitening or yellowing under normal conditions. Truly invisible throughout treatment.

Shape Memory Technology

How shape memory technology works

Direct 3D Printing

Printed tooth-by-tooth — no thermoforming. Precise thickness per tooth for optimal orthodontic force.

Shape Memory Effect

ta28 recovers its programmed shape at body temperature. Warm-water dip for 30s gives a perfect fit.

Light & Continuous Force

Gentle continuous force instead of heavy spikes — reduces pain and improves outcomes.

Adjustable Strain & Resilience

Per-tooth thickness adjustment. Shape Memory Aligner resists full-arch deformation when bent.

Feature
DPA (Graphy)
Thermoformed
Manufacturing
Direct 3D Print
Thermoforming
Thickness control
Per tooth
Uniform sheet
Force type
Light & continuous
Heavy then drops
Shape recovery
✓ Yes
✗ No
Occlusal accuracy
✓ Precise
✗ Approximate
Heat disinfection
✓ 100°C
✗ No
Treatment time
Up to 50% faster
Standard
Attachments
Usually none
Often required
Aligner change
Every 7 days
Every 14 days
Light & Continuous Force
Light & Continuous Force
SMP delivers sustained force vs thermoplastic stress drop-off.
Shape Memory Effect
Shape Memory Effect
ta28 recovers its programmed shape at body temperature.
Shape-Driven Biomechanics
Shape-Driven Biomechanics
Adjustable strain & resilience — precise occlusal reproduction.

Treated Cases

Conditions we treat

Our orthodontic team reviews every case before manufacturing.

Crowding

Insufficient room to fit all teeth, leading to plaque accumulation.

Cross Bite

Upper and lower jaws are misaligned.

Over Jet

Upper anterior teeth protrude excessively in front of lower front teeth.

Over Bite

Upper teeth abnormally cover the lower teeth.

Open Bite

Excessive space between upper and lower front teeth.

Spacing

Wide spaces between teeth that can cause gum problems.

Patient Guide

How to use your DPA aligners

01

Inserting

  • Soften in lukewarm water for 30 seconds
  • Push gently over front teeth
  • Apply equal pressure on back molars until it snaps in
  • Use aligner chewies if provided
02

Wearing

  • Wear at least 22 hours daily
  • Remove only when eating or brushing
  • First 48 hours are critical — wear consistently
  • Change to the next aligner every 7 days
03

Cleaning

  • Rinse with warm (not hot) water after each removal
  • Sterilize daily in warm water for 1 minute
  • Store in the provided case when not in use
  • Never use denture cleaner or mouthwash on aligners

Important: Always brush after meals before reinserting. If pain or mouth ulcers don't resolve within a few days, contact your orthodontist immediately.

Patient Safety InformationUnderstanding How Your Body May Respond to Aligner TreatmentClick to read full details

As with any medical device placed in the oral cavity, clear aligners may cause tissue responses in a small number of patients. The information below helps you and your clinician identify, prevent, and manage these reactions early and effectively.

ℹ️Note: The tissue responses described below are not unique to DPA aligners — they are documented across all clear aligner systems. DPA's manufacturing process, material selection, and clinical protocols are specifically designed to minimize their incidence. If you experience any unusual oral symptoms during treatment, discontinue use and consult your orthodontist before resuming.

Material Sensitivity

Hypersensitivity Reaction
Signs & Symptoms
  • Mild: roughness, itching, or ulcers on the oral mucosa — consult your orthodontist if persisting beyond 3 days.
  • Severe (Emergency): progressive swelling of oral tissues, difficulty swallowing, or breathing difficulty — discontinue immediately and seek urgent medical care.
At Risk
  • Patients with a prior history of allergic reactions to plastic materials or dental devices.
  • Individuals with sensitive skin, atopic conditions, or pre-existing oral infections.
  • Patients concurrently exposed to MDA or HDI compounds in occupational settings.
DPA Advantage

Graphy TA-28 resin undergoes oxygen-free polymerization — eliminating residual uncured oligomers that are the primary source of allergen release in conventional thermoformed aligners. This significantly reduces the risk of Type IV delayed hypersensitivity reactions.

Management
  • Discontinue aligner use immediately upon onset of moderate or severe symptoms.
  • Administer hydrocortisone injection or topical corticosteroid as appropriate.
  • Saltwater rinses and tebodont gel for mucosal relief.
  • Do not resume aligner therapy without clinical reassessment.

Traumatic Ulcers

Mechanical Irritation
Cause

Traumatic ulcers arise from mechanical irritation by aligner margins that are inadequately finished, or from attachment pillars with rough or sharp edges pressing against soft tissue during function and parafunction.

DPA Advantage

All DPA aligners are 3D-printed with smooth, anatomically contoured margins — eliminating the trimming inaccuracies common in thermoformed trays. Attachment pillars undergo mandatory polishing protocols before aligner delivery.

Action
  • Inspect the gingival margin and buccal mucosa at each clinical review.
  • Report any persistent redness, blanching, or ulceration at the gum line to your orthodontist promptly.
  • Do not attempt to trim or adjust the aligner at home.
Management

Topical anaesthetic gel for symptomatic relief. If the ulcer does not resolve within 5–7 days of aligner removal, a clinical assessment is required to rule out other pathology.

Stomatitis

Hygiene-Related Reaction
Cause

Stomatitis associated with aligner use is predominantly caused by poor intraoral hygiene or inadequate aligner disinfection, leading to accumulation of bacterial biofilm, Candida species, and food residues beneath the aligner.

Prevention
  • Brush and floss after every meal — without exception — before reinserting aligners.
  • Sterilize aligners daily by immersing in hot water (100°C) for 1 minute.
  • Use of an ultrasonic cleaner is strongly recommended for complete biofilm removal.
  • Never store aligners in a wet or unclosed case — a dry, sealed case prevents microbial growth.
General Health
  • Maintain adequate hydration throughout treatment — saliva flow is a natural antibacterial defense.
  • A daily multivitamin supporting immune function (Vitamins C, D, and Zinc) is advisable during aligner therapy, particularly in patients prone to oral ulceration.
  • Patients on immunosuppressants, steroids, or antibiotics should inform their orthodontist before starting treatment.
Treatment
  • Warm saltwater rinses (1 teaspoon per 250 ml) four times daily.
  • Tebodont gel applied to affected mucosa after meals.
  • Pause aligner use until mucosal inflammation fully resolves.
  • If candidal infection is suspected (white plaques, burning sensation), antifungal therapy may be indicated — consult your physician.

If you have a known history of allergies — particularly to plastics, dental materials, or skin sensitivities — please inform your orthodontist before beginning aligner treatment. This allows your clinician to take appropriate precautions from the outset.

Tissue reactions during aligner therapy, while uncommon, are a recognized and manageable clinical occurrence. If a reaction does arise, it is typically mild, resolves promptly with appropriate care, and does not necessarily mean treatment cannot continue. Your orthodontist will guide you through the right steps.

DPA OS

Run the entire aligner factory from one platform

DPA OS connects doctors, designers, manufacturing, QC, finance and shipping — with realtime updates and an AI ops supervisor watching every case.

Case Management

Doctor portal with 100MB STL/ZIP/MP4 uploads, plans and timeline.

Manufacturing Kanban

12-stage board: incoming → printing → QC → packaging → delivered.

Live

Realtime Operations

Live chat per case, shift handovers, printer status.

AI Ops Supervisor

Event-driven alerts on bottlenecks and idle printers.

Payments & Shipping

InstaPay flow with proof verification and shipment tracking.

Enterprise Security

Role-based access, audit log and signed downloads.

FAQ

Frequently asked questions

Do you want to place an order?

Send us your case now and our team will take it from there.

Contact

Get in touch with DPA

Reach our team directly on WhatsApp or follow us across platforms.